Filling a Tank Without Entraining Bubbles

How the air gets in, and five ways to stop it

Most of the bubbles that appear during filling are air dragged in through the surface. Remove the drop height and far less gets in.

Large drop: air is dragged indrop hv = √2gh20 cm: about 2 m/sentrained bubblesRun it along the wall / keep it submergednozzle tip submergedfilm flow along wallquiet surface

← 図は横にスクロールできます / Scroll the figure sideways →

Fig. 1: At the same flow rate, a remaining drop height drags air through the surface (left), while a submerged tip or wall film does not (right).

Key points

  • The amount of air that gets in is set by the drop height.
  • Fine bubbles are slow to rise: a 0.1 mm bubble takes about 31 minutes to rise 300 mm in oil.
  • Five countermeasures: a longer inlet pipe, baffles, mesh, PLC control and the Bubble Eliminator.

Start with a familiar example: the physics of pouring beer without a mountain of foam

1. Why filling entrains air: five mechanisms

1. Air entrainment by a plunging jet

When a free-falling liquid column strikes the liquid surface, the surface is drawn inward and a sheath of air is dragged into the bulk. This is the single largest source of entrained air during filling.

The impact velocity is set by the drop height h alone (v=2gh). For low-viscosity liquids such as water, the critical impact velocity is roughly 0.8-1.2 m/s. Above it, the entrained air volume rises with velocity to the power of 1.5 to 2.

Cutting the drop height from 300 mm to 50 mm lowers the impact velocity from 2.4 m/s to 1.0 m/s - an order-of-magnitude reduction in entrained air.

2. Splashing and film rupture

At the impact point a thin liquid dome rises and, when it ruptures, seals off spherical pockets of air. Each returning droplet adds further small bubbles.

Whether the film ruptures is governed by the Weber number We = ρv²d/σ. Liquids with low surface tension (surfactant-laden cleaners, paints) rupture more easily and foam more at the same drop height.

3. Surface vortex at the outlet

A free vortex above the tank outlet stretches an air core down from the surface, which is then sucked straight into the pump. It is most likely when the incoming jet sets the surface rotating.

As a rule of thumb, keep the outlet submerged by 1.5-2 times its bore and fit a vortex breaker (cross plate) just upstream; the air core then cannot reach the outlet. This presupposes that the incoming flow is not tangential and does not spin the surface.

4. Dissolved air coming out of solution

Bubbles do not only come from outside - they also come out of the liquid. Hydraulic oil holds 8-10 % air by volume in solution at atmospheric pressure. Wherever static pressure falls, at an orifice or along a suction line, that air is released as fine bubbles.

The larger the drop height, the more the surface is agitated, increasing both contact area and contact time with air - so the dissolved-air content itself rises, and that much more air comes out as bubbles at every pressure drop downstream.

5. Foam stability and rise velocity - why prevention beats removal

The rise velocity of a small bubble can be estimated from Stokes' law, v = ρgd²/(18μ). It is proportional to the square of the bubble diameter and inversely proportional to the viscosity, so a bubble one tenth the diameter rises one hundred times more slowly. The table below gives the values by diameter.

Table: bubble diameter, rise velocity, and the time to rise 300 mm
Bubble diameter ⌀Water (1 mPa·s)Oil (30 mPa·s)
Rise velocityTime to rise 300 mmRise velocityTime to rise 300 mm
0.01 mm0.054 mm/sabout 1.5 h0.0016 mm/sabout 2.2 days
0.02 mm0.22 mm/sabout 23 min0.0064 mm/sabout 13 h
0.05 mm1.4 mm/sabout 3.7 min0.040 mm/sabout 2.1 h
0.1 mm5.4 mm/sabout 55 s0.16 mm/sabout 31 min
0.2 mm16 mm/sabout 18 s0.64 mm/sabout 7.8 min
0.5 mm55 mm/sabout 5 s4.0 mm/sabout 75 s
1 mm110 mm/sabout 3 s16 mm/sabout 19 s

Conditions: water at 20 °C (998 kg/m³); oil at 880 kg/m³. The bubble surface is treated as immobile, as it is in liquids that carry surfactants or contamination. All oil rows, and the water rows up to 0.1 mm, are Stokes-law values. The water rows from 0.2 mm up are corrected for the extra drag that Stokes’ law ignores (Schiller–Naumann correlation), because Stokes’ law would give too high a velocity there.

A 0.1 mm bubble needs about 55 seconds to rise 300 mm in water, and about 31 minutes in a 30 mPa·s oil. On a line with a cycle time of tens of seconds, entrained fine bubbles simply travel on to the next process.

Surfactants and proteins adsorbed at the interface stabilise the films, so surface foam persists. For this reason, keeping air out at the filling step achieves more, at lower cost, than removing bubbles after they are in.

2. Drop height and impact velocity

The velocity at which the liquid strikes the surface after falling a height h is v=2gh.

Drop height hImpact velocity vWhat happens (water-like liquid)
20 mm0.63 m/sVirtually no entrainment
50 mm0.99 m/sAt the entrainment threshold
100 mm1.4 m/sContinuous entrainment begins
300 mm2.4 m/sBubbles carried deep into the bulk
1,000 mm4.4 m/sSplashing and foaming dominate

The critical impact velocity depends on viscosity, surface tension, jet diameter and jet turbulence; for water it is around 0.8-1.2 m/s.

How fast an entrained bubble rises is tabulated by bubble diameter under "5. Foam stability and rise velocity" in section 1.

3. Four design principles

Principle 1: Drive the drop height toward zero

Keep the nozzle below the surface (submerged filling), feed from the bottom through a dip tube, or lower the nozzle as the level rises. Impact velocity depends on drop height alone, so of the four principles this one has the largest effect at the lowest cost.

Principle 2: Slow the flow and run it along a wall

Enlarge the cross-section to reduce velocity, and convert free fall into film flow with an impact plate or along the tank wall. It is the same physics as pouring beer down the inside of a tilted glass.

Principle 3: Create a quiet zone at the surface

Separate the fill zone from the suction zone with a baffle so that surface turbulence and swirl never reach the outlet. A vortex breaker and sufficient submergence stop the air core.

Principle 4: Provide time and a path for bubbles to rise

Secure residence time (a hydraulic reservoir of 3-5 times the pump flow per minute is the usual guide) and shorten the rise path with inclined plates. Whatever fine and dissolved air remains is removed with our Bubble Eliminator.

4. Five countermeasure plans

1 Impact plate (jet to film)2 Baffle platelow opening only3 Inclined plates (short rise path)4 Vortex breakersubmergence > 1.5-2 x boreFill chamber (bubbles rise here)Suction chamber (quiet zone)

← 図は横にスクロールできます / Scroll the figure sideways →

Fig. 2: The elements of Plan B - an impact plate reduces the drop height, a baffle creates a quiet zone, inclined plates shorten the rise path, and a vortex breaker plus submergence stop air-core suction.
Plan A: Extended inlet pipe

Extend the inlet pipe to near the tank bottom and fill below the surface

What it involves

  • •Extend the inlet pipe (a dip tube) to near the bottom of the tank. Once its tip is under the liquid, nothing falls onto the surface, so the drop height is zero.
  • •Leave a gap between the tip and the tank bottom. If the gap is too narrow it throttles the flow and the pressure loss rises.
  • •Cut the tip at an angle or turn it sideways so the flow runs along the bottom or the wall, and widen the tip to lower the outlet velocity.
  • •Drill a small hole (a siphon-break hole) in the pipe above the liquid level. It stops the tank contents from siphoning back into the pipe when the pump stops.
  • •Place the tip away from the tank outlet, so that bubbles leaving the pipe are not carried straight into the outlet.
Short pipe: falls onto the surfacedrop heightair isdragged insurfaceExtended to the bottom: nothing falls1 Small hole(above the surface)2 Gap3 Along the bottom4 Outletsurface1 Stops back-siphoning when the pump stops 2 Not touching the bottom3 Tip cut at an angle 4 Kept away from the pipe tipA 20 cm drop gives an impactspeed of about 2 m/s

← 図は横にスクロールできます / Scroll the figure sideways →

Fig.: Left, a short pipe: the liquid falls onto the surface and drags air in. Right, the pipe extended to near the bottom: its tip is under the liquid, so nothing falls onto the surface.

Strengths

  • It is only a longer pipe, so the cost is small. No moving parts, no power supply and no controls.
  • Once the tip is submerged, raising the flow rate does not entrain air through the surface.

Limits and cautions

  • From the start of filling until the tip is submerged, the drop height is still there. When filling an empty tank, throttle the flow for that period (combine with Plan D).
  • Air that was in the pipe, and bubbles mixed in upstream of it, are released into the liquid as they are. Bubbles released near the bottom have the longest distance to rise to the surface.
  • It tends to stir up sediment on the bottom. For liquids that need cleaning in place, both the inside and the outside of the pipe have to be cleaned.
Plan B: Classic

Baffles and flow-conditioning plates: a mechanical quiet zone

What it involves

  • •A vertical baffle divides the fill chamber from the suction chamber, connected only by a low opening (below one third of the liquid depth, with a face velocity under about 0.1 m/s).
  • •An impact (diffuser) plate under the inlet converts the free-falling jet into a film flowing along the wall.
  • •Stack inclined plates in the liquid, a few tens of millimetres apart. A bubble then only has to rise to the underside of the plate just above it, not all the way to the surface. Bubbles coalesce under the plate and escape upward along it.
  • •Keep the outlet submerged by 1.5-2 bore diameters with a vortex breaker just upstream, and add a surface board to stop foam from accumulating.

Why inclined plates shorten the rise path

No plates: rise to the surface300 mmabout 31 min toreach the surfacesurfaceWith plates: rise only to the next plate30 mm①②③1 Rise to the underside of the plate above (30 mm, about 3 min)2 Bubbles merge under the plate and grow3 Slide up along the plate and leave from its upper edgeOne tenth of the distancetakes one tenth of the time

← 図は横にスクロールできます / Scroll the figure sideways →

Fig.: Without plates a bubble has to rise all the way to the surface. With plates it only has to reach the underside of the plate just above it. Times are for a 0.1 mm bubble in a 30 mPa·s oil with plates 30 mm apart.

Strengths

  • No moving parts, no power supply and no controls, so there is very little that can fail.
  • Usually just added plates in an existing tank, so the cost is minimal.

Limits and cautions

  • Effective against visible bubbles and surface foam only; fine and dissolved air remain.
  • Needs tank volume for the quiet zone and residence time, which conflicts with compact designs.
  • Falls off its design point when level, flow rate or viscosity change; it cannot adapt to a mixed-product line.
Plan C: Simple retrofit

Mesh and perforated plates: dispersion plus coalescence

What it involves

  • •A perforated plate or shower-head diffuser under the inlet splits one jet into many weak streams and spreads its kinetic energy.
  • •A wettable wire mesh (coalescing mesh) in the liquid lets bubbles attach and merge; a tenfold increase in diameter gives a hundredfold rise velocity.
  • •A non-woven or sintered element ahead of the outlet can capture bubbles and filter particles at the same time.
  • •Typical design values: 1-3 mm openings, face velocity under 0.1 m/s, pressure drop of a few kPa.

Strengths

  • Easy to retrofit with little downtime, and the parts are inexpensive.
  • Addresses the fine bubbles baffles leave behind by coalescing them and speeding their rise.

Limits and cautions

  • It clogs: differential-pressure monitoring and periodic cleaning are mandatory.
  • If the jet is too fast, the mesh breaks the bubbles into finer ones and there are more bubbles than before. The flow must be slowed down before it reaches the mesh.
  • Viscous liquids pass poorly, so pressure drop and hold-up become issues.
Plan D: Intelligent

PLC control: hold the impact velocity below its critical value

What it involves

  • •A level sensor (pressure, ultrasonic or capacitive) tracks the surface continuously; the controller computes the drop height h to the nozzle tip and trims flow with a VFD pump or proportional valve so that v=2gh never exceeds the critical velocity.
  • •Three-stage profile: (1) slow start until the nozzle is submerged, (2) full-rate fill while submerged, where no entrainment occurs, (3) slow finish for an accurate, undisturbed stop.
  • •Level-following nozzle: a servo or air cylinder keeps the nozzle tip permanently below the surface, physically eliminating the drop height.
  • •Close the loop on foam: an optical or ultrasonic foam sensor measures the foam layer, and the controller slows the fill and inserts a settling dwell when it exceeds a threshold.
  • •Correct for viscosity from temperature and keep a recipe per liquid. On the suction side, interlock pump slow-down and stop at low level to prevent a suction vortex.
  • •Log the velocity profile and foam index for every fill so they can be correlated with yield.
FlowTimeLevel1 Slow startuntil nozzle submerged2 Full fillsubmerged: no entrainment3 Slow finishaccurate stop,calm surfaceLevel sensor -> PLC (keeps v = √2gh below critical) -> VFD / proportional valve -> nozzle, trimmed by foam sensor

← 図は横にスクロールできます / Scroll the figure sideways →

Fig. 3: A three-stage PLC filling profile. The controller derives the drop height from the level and maximises flow within the critical impact velocity.

Strengths

  • Holds the impact velocity constant as the level rises, keeping entrainment low without lengthening the cycle time.
  • Adapts to mixed products, different levels and changeovers by switching recipes.
  • The logged data lets you verify the correlation with defects after the fact.

Limits and cautions

  • Initial cost for sensors, valves and controls, plus engineering and validation effort.
  • Sensors need cleaning and drift maintenance; without calibration the readings drift and the control no longer does what it was designed to do.
  • If the mechanical measures (drop height and nozzle shape) are skipped, control alone cannot keep entrainment down.
Plan E: Combined with the Bubble Eliminator

Remove the fine bubbles and dissolved air that prevention leaves behind, with the Bubble Eliminator

What it involves

  • •Plans A to D prevent entrainment. Fine bubbles already dispersed in the liquid, and air dissolved in it, will not leave in any practical length of time if the liquid is simply left to stand.
  • •Our Bubble Eliminator generates a swirling flow in a tapered tube, concentrates bubbles in the low-pressure core and expels them through a vent. Installed in a circulation loop, it treats the tank contents continuously.
  • •Cutting the inflow of air by an order of magnitude mechanically and removing the remainder with the Bubble Eliminator is the practical balance of cost and effect.

Strengths

  • Reduces fine and dissolved air as well, and is insensitive to variation in level or filling conditions.
  • No moving parts, and it fits into existing circulation piping.

Limits and cautions

  • Requires a circulation pump, piping space and a pressure differential.
  • If the drop height on the fill side is left untouched, the throughput will not keep up.

5. Comparing the plans

Initial cost

  • ALonger pipeLow
  • BBafflesadded platesLow
  • CMeshLow
  • DPLC controlMedium to high
  • EBubble EliminatorMedium

Large bubbles / surface foam

  • ALonger pipeonce the tip is submergedExcellent
  • BBafflesExcellent
  • CMeshGood
  • DPLC controlExcellent
  • EBubble EliminatorGood

Fine bubbles0.1 mm class

  • ALonger pipereduces inflowGood
  • BBafflesPoor
  • CMeshpromotes coalescenceFair
  • DPLC controlreduces inflowGood
  • EBubble EliminatorExcellent

Dissolved air

  • ALonger pipePoor
  • BBafflesPoor
  • CMeshPoor
  • DPLC controlFair
  • EBubble EliminatorGood

Adapts to level change / mixed products

  • ALonger pipelevels above the tipGood
  • BBafflesPoor
  • CMeshFair
  • DPLC controlExcellent
  • EBubble EliminatorGood

Impact on cycle timetime per unit

  • ALonger pipeNone
  • BBafflesNone
  • CMeshpressure dropSmall
  • DPLC controlslow only at start and finishSmall
  • EBubble EliminatorNone

Maintenance

  • ALonger pipeAlmost none
  • BBafflesAlmost none
  • CMeshCleaning and ΔP monitoring
  • DPLC controlSensor calibration
  • EBubble EliminatorVent inspection

Ratings from best to worst: Excellent, Good, Fair, Poor

6. The order to work in

1

Quantify the present state

Record the drop height from nozzle tip to surface, the flow rate, the range of level change, the liquid viscosity and surface tension, and the cycle time. Computing v=2gh from the drop height tells you on the spot whether entrainment is occurring.

2

Cut the drop height - this decides most of the outcome

Use a nozzle extension, dip tube, bottom feed or impact plate to bring the impact velocity under 1 m/s. Of the five steps, this is the least work for the largest effect.

3

Fix the quiet zone and the suction condition

Design the baffle, the vortex breaker and the submergence. Up to this point no power or control is needed.

4

Add PLC control if variability remains

If the level swings widely, if conditions change between products, or if cycle time cannot be sacrificed, the investment in level-feedback flow control pays back.

5

Remove the remaining fine bubbles with the Bubble Eliminator

If yield, bulk modulus, noise or temperature rise still show the effect, add our Bubble Eliminator in the circulation loop to reduce fine and dissolved air.

Contact Us

Feel free to ask for consultation or quotation